Call UsCall Us : 08045804997
Change Language
Cold Insulation Pipe Section
Cold Insulation Pipe Section

Cold Insulation Pipe Section

Price 70 INR/ Meter

Cold Insulation Pipe Section Specification

  • Usage & Applications
  • Thermal insulation for chilled and cold pipeline systems, HVAC ducts, cold storage, and refrigeration applications
  • Material
  • Rigid Polyurethane Foam (PUF)
  • Type
  • Pipe Section
  • Grade
  • Industrial
  • Tensile Strength
  • Min 15 kg/cm2
  • Density
  • 40 Gram per cubic centimeter(g/cm3)
  • Heat Deflection Temperature
  • 80C to 100C
  • Width
  • 1 Meter
  • Length
  • 1 Meter
  • Thickness
  • 25 mm to 100 mm
  • Size
  • Customizable as per pipe diameter
  • Color
  • Yellow
  • Finish Type
  • Smooth outer surface
  • Fitting Type
  • Slit for easy installation
  • Standards
  • Complies with IS 12436
  • Shape
  • Cylindrical
  • Operating Temperature Range
  • -180C to +110C
  • Thermal Conductivity
  • 0.022 W/mK
  • Odor
  • Odorless
  • Fire Resistance
  • Self-extinguishing
  • Water Absorption
  • <1% by volume
  • Compressive Strength
  • Min 2.1 kg/cm2
 

Cold Insulation Pipe Section Trade Information

  • Minimum Order Quantity
  • 1000 Meter
  • Supply Ability
  • 100000 Per Week
  • Delivery Time
  • 3-5 Days
  • Main Domestic Market
  • All India
 

About Cold Insulation Pipe Section

EPS pipe sections are widely used in Pipe line insulation for centralised air conditioning. We manufacture pipe sections for insulation of pipe lines of different diameters ranging from 15mm to 1000mm and insulation thickness of 25mm to 150 mm.

 

  • Dimensions: From 15mm to 600mm Dia
  • Weight (kg): Depending on pipe size and density
  • Density: 12Kg/cum to 32Kg/cum
  • Usage: Pipe line insulation for centralised airconditioning

 



Superior Performance for Demanding Applications

Designed for applications including chilled pipelines, HVAC systems, and refrigeration, the Cold Insulation Pipe Section offers robust thermal resistance within a wide operating temperature range, from -180C to +110C. The product's rigid polyurethane foam construction and precise design deliver consistent and reliable insulation, maintaining energy efficiency and reducing operational costs in industrial environments.


Easy Installation and Long-Lasting Protection

Featuring a smooth outer surface and slit-type fitting, these pipe sections simplify mounting and adjustment during installation. The product's odorless and moisture-resistant properties ensure hygiene and durability, while the self-extinguishing material enhances workplace safety. Customizable dimensions address unique pipeline requirements for a seamless fit and optimal performance.

FAQ's of Cold Insulation Pipe Section:


Q: How do I install the Cold Insulation Pipe Section on my existing pipeline?

A: The pipe section is designed with a longitudinal slit, allowing it to be easily wrapped around your pipeline without dismantling existing structures. Simply open the slit, position the section around the pipe, and secure as needed for a snug, effective insulation.

Q: What are the benefits of using PUF insulation for cold pipelines?

A: Rigid Polyurethane Foam (PUF) provides excellent thermal insulation due to its low thermal conductivity (0.022 W/mK), significantly reducing heat or cold loss. Its lightweight, self-extinguishing, and moisture-resistant nature ensures long-term performance and reduced energy costs.

Q: Where can these pipe sections be used effectively?

A: These insulation pipe sections are suited for use in chilled and cold pipeline systems, HVAC ducts, cold storage facilities, and various refrigeration applications, meeting the rigorous demands of industrial and commercial environments.

Q: What standards do these pipe sections comply with?

A: Our product is manufactured according to IS 12436, ensuring high-quality insulation performance, durability, and safety as required by Indian industrial standards.

Q: How do I select the appropriate size and thickness for my application?

A: The sections come in thicknesses from 25 mm to 100 mm and can be customized according to your pipe's diameter. For optimal insulation, select the thickness and size based on your pipeline's diameter and temperature requirements, or contact our technical team for guidance.

Q: What makes these pipe sections fire-resistant and safe for industrial use?

A: Manufactured from self-extinguishing material, the pipe sections are designed not to propagate flame. Their minimum compressive and tensile strengths (2.1 kg/cm2 and 15 kg/cm2 respectively) make them durable and suitable for industrial settings where safety is critical.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in EPS Pipe Sections Category

Thermocol Pipe Sections

Thermocol Pipe Sections

Price 350 INR / Meter

Minimum Order Quantity : 100

Thickness : 15 mm to 100 mm and above as required

Size : Suitable for pipe sizes ranging from 15 mm to 350 mm NB

Width : Varies as per pipe diameter (Standard sizes available)

Heat Deflection Temperature : < 70C

EPS Pipe Sections

EPS Pipe Sections

Price 70 INR / Meter

Minimum Order Quantity : 1000 Meters

Thickness : 25 mm to 150 mm

Size : Suitable for pipes 1/2 to 36 diameter

Width : Customizable as per pipe diameter

Heat Deflection Temperature : 70C to 80C